Design Control • Medical Devices • R&D • Product Development • Engineering • Design of Experiments • Iso 13485 • Cross Functional Team Leadership • Biomaterials • Product Launch • Manufacturing • Biomedical Engineering • Fda • Product Design • Quality System • Minitab • Medical Device Product Development • Validation • V&V • Commercialization • Design For Manufacturing • Capa • Iso 14971 • Six Sigma • Process Simulation • Fmea • Solidworks • Injection Molding • Manufacturing Engineering • Research and Development
Ethicon, Inc.
Director, Biosurgery R and D Front-End Innovation
Bd Jan 1997 - Nov 2000
Senior Engineer
Education:
New Jersey Institute of Technology 1996 - 1997
Master of Science, Masters, Mechanical Engineering
Boston University 1989 - 1994
Bachelors, Bachelor of Science, Aerospace Engineering
Skills:
Design Control Medical Devices R&D Product Development Engineering Design of Experiments Iso 13485 Cross Functional Team Leadership Biomaterials Product Launch Manufacturing Biomedical Engineering Fda Product Design Quality System Minitab Medical Device Product Development Validation V&V Commercialization Design For Manufacturing Capa Iso 14971 Six Sigma Process Simulation Fmea Solidworks Injection Molding Manufacturing Engineering Research and Development
Languages:
Romanian
Us Patents
Hypodermic Syringe With Selectively Retractable Needle
Richard Caizza - Barry Lakes NJ Simon Cohn - North Arlington NJ Jonathan Gabel - Randolph NJ
Assignee:
Becton, Dickinson and Company - Franklin Lakes NJ
International Classification:
A61M 500
US Classification:
604110, 604195
Abstract:
A hypodermic syringe with a selectively retractable needle includes an elongate barrel having an open proximal end, an open distal end and a hollow bore. The syringe includes an elongate plunger including a hollow outer housing having an open proximal end and an open distal end. The plunger has a hollow inner sleeve defining a cavity therein. The plunger has releasable engagement elements preventing relative axial movement between the outer housing and the inner sleeve, the elements allowing the relative axial movement when released and a distal stopper. There is an open cutter mounted at a proximal end of the inner sleeve to cut through the stopper to expose the cavity in the inner sleeve when the engagement elements are released and sufficient distal axial force is applied to the plunger. The syringe has a hub housing with an open proximal end having an inwardly projecting shoulder, a hub with a proximal flange and an axial stem, sized to fit within the hub housing. There is a spring disposed about the stem between the flange and the shoulder.
Rajesh Pendekanti - Bridgewater NJ Simon Cohn - North Arlington NJ
Assignee:
Ethicon, Inc. - Somerville NJ
International Classification:
A61B 1814
US Classification:
606 51, 606170, 606208
Abstract:
A surgical instrument useful in harvesting blood vessels such as veins and arteries and for manipulating and grasping tissue. The instrument has a pair of jaws and a closing tube to open and close the jaws. One of the jaws is preferably movable between the open and closed positions and has an insert for providing lateral strength and stiffness while providing the flexibility necessary to open and close the jaws.
Craig D. Newman - Montvale NJ Charles G. Hwang - Ridgewood NJ Richard A. Flowers - Vernon NJ Glade H. Howell - Sandy UT Simon Cohn - North Arlington NJ
Assignee:
Becton Dickinson and Company - Franklin Lakes NJ
International Classification:
A61B 1732
US Classification:
606167, 30151, 30335
Abstract:
A shielded surgical scalpel includes an elongate handle defining a longitudinal axis and having a proximal portion and a distal portion. A blade is fixedly attached to the handle. A shield is mounted onto the handle. The shield is movable between a distal position where the shield prevents inadvertent access to the blade and a proximal position where the shield exposes the blade for use.